The government published the National Risk Register 2026 on 14 July. It runs to 223 pages, and this edition marks a significant shift in how cyber risk to critical infrastructure is presented.
The most important parts are not necessarily the risks that attract the biggest headlines. They are the assumptions that appear repeatedly across the document: how long recovery may take, what operators must prove before services can safely return, and how artificial intelligence is changing the speed and accessibility of cyber attacks.
What is new
The 2026 register introduces several cyber and technology scenarios that did not appear in the previous edition.
There is a new cyber attack scenario for water infrastructure, a new cyber risk covering data infrastructure, and a new scenario involving an attack on police systems. There is also a separate risk covering national disruption to data infrastructure.
That matters because the government formally designated data infrastructure as part of the UK’s Critical National Infrastructure in 2024. It now has explicit treatment within national risk planning.
The register also introduces a “digital resilience failure” scenario. It reflects the lessons of the July 2024 global IT outage and recognises that dependency, concentration and fragility alone can disrupt critical services.
You do not necessarily need an attacker to lose critical services. A failure affecting a sufficiently important supplier, platform or software component may be enough.
Taken together, the cyber content is more extensive and more sector-specific than in the previous register. That expansion is significant in itself. The risks the government chooses to include are the risks it expects departments, agencies and operators to plan against.
The likelihood number needs careful handling
The register groups several scenarios under “cyber attacks on infrastructure” and gives the category an average impact score of 3, meaning moderate, and an average likelihood score of 4.
For malicious risks, a likelihood score of 4 corresponds to a 5% to 25% chance of the assessed reasonable worst-case scenario occurring at least once within the register’s two-year assessment period.
That is a striking planning range, but it needs describing accurately.
It is an average score for a grouped category containing different scenarios, actors and levels of disruption. It does not simply state that there is a one-in-four chance of any significant cyber attack on UK infrastructure.
Nor does it predict that such an event will happen. Reasonable worst-case scenarios are planning assumptions: plausible, challenging manifestations of a risk against which government and operators should prepare.
Even with those qualifications, the message is clear. Nationally consequential cyber disruption sits firmly inside the government’s active planning range. The government is not treating it as a remote or theoretical possibility.
The recovery sections matter more than the likelihood score
Read the cyber scenarios in sequence and a pattern emerges.
For health, the register describes a phased return of priority services over several months.
Water tells a similar story. Recovery may take several months. Operational technology components may be specific to an individual facility and may require replacement, rebuilding or reconfiguration. The register also makes an especially important point: before safely restoring systems, the operator needs assurance that they have removed the attacker from the network.
Policing recovery could take months and, in some cases, as long as 18 months.
Data infrastructure disruption may continue for months. Where attackers have destroyed, corrupted or sold data, restoration may take years, and some information may not be recoverable at all.
The financial market infrastructure scenario describes the longest timeline: recovery extending over a number of years, with the register treating permanent data loss or corruption as a strong possibility.
Months. Eighteen months. Years. Potentially permanent loss.
These are not predictions. They are reasonable worst-case planning assumptions. But the pattern is difficult to ignore.
Recovery depends on proof, not just restoration
Once a capable actor has compromised operational technology, identity systems or the underlying data layer, recovery goes beyond restoring a backup and reopening the service.
Operators must trust systems again. They must test data integrity. They must map dependencies and confirm they have removed all persistence. They need confidence that restoration will not reconnect the attacker or reintroduce compromised systems into production.
The water scenario states this particularly clearly: recovery depends on assurance that the operator has completely removed the attacker.
That is a detection, investigation and forensic-readiness problem.
If the telemetry, evidence and investigative capability do not exist before the incident, the organisation cannot create them retrospectively while already under pressure to restore services.
The register repeatedly warns about AI
A second pattern appears across many of the cyber scenarios.
The entries covering gas, electricity, fuel, transport, data infrastructure, water, policing and civil nuclear repeat, or closely echo, the warning that artificial intelligence can automate aspects of launching cyber attacks.
The register says this makes attacks faster and more efficient while lowering the barrier to entry. The health and telecommunications scenarios make related points, although the wording differs. The financial scenarios do not contain the same repeated warning.
This does not mean that every attacker is suddenly operating autonomously or that every intrusion will happen at machine speed.
It means the government expects AI to increase the pace, scale and accessibility of existing attack methods.
AI can increasingly accelerate or partially automate tasks that previously required more time, specialist knowledge or manual effort. Attackers can test more approaches, process more information, adapt tooling more quickly and operate across more targets.
My shorthand is that the race has changed class.
Attacking infrastructure used to resemble go-kart racing: skilled people, significant manual effort and usually one target at a time.
AI moves parts of the contest closer to Formula 1. The underlying objective may be the same, but the speed, engineering and operating tempo are categorically different.
That has consequences for defenders. A detection and response model designed around human-speed attacks, periodic review and lengthy enrichment cycles will struggle when AI compresses or automates parts of the attack chain.
What the register implies
Put the findings together, the published likelihood band, the recovery timelines and the increased speed and scale enabled by AI, and my conclusion is that compromise is now a sufficiently credible planning scenario that critical infrastructure operators cannot base resilience on prevention alone.
That is my interpretation of the register, rather than a sentence the document states directly.
Prevention still matters. So do secure architecture, segmentation, vulnerability management, supply-chain assurance, continuity planning, manual workarounds and tested restoration.
But the period between intrusion and operational impact becomes one of the most important control points.
Can the organisation detect a capable actor after they have gained access but before they have disrupted operations, corrupted data or established persistence across the environment?
Would it investigate quickly enough to understand what has happened?
Could it contain the attacker without causing greater operational harm?
And does it retain enough trustworthy evidence to demonstrate that systems are safe to restore?
Detection and forensic readiness do not replace prevention or recovery. They connect them.
What the register does not say
The register describes the risks and the consequences, but it does not prescribe the operational controls needed to close the gap.
It does not tell an operator what telemetry to retain, how quickly analysts should review activity, how to bring identity, IT and operational technology evidence together, or what level of forensic readiness supports safe restoration.
That is not necessarily a criticism. The National Risk Register is a national planning document, not a detailed cyber control framework.
But the gap matters.
The energy scenarios refer to the Network and Information Systems Regulations 2018 as part of the framework requiring operators to take appropriate security measures.
At the same time, Parliament is considering the Cyber Security and Resilience Bill, which would amend and expand that regime. The government’s own case for the Bill is that the existing regulatory framework has not kept pace with the threat landscape, the growth of digital dependencies or the importance of critical suppliers.
The register describes the environment.
The Bill is an acknowledgement that the regulatory framework now needs to catch up with it.
Three questions for the next risk committee
For anyone responsible for running or securing critical infrastructure, I would take three questions from the register.
- If a capable actor established persistence in our environment today and deliberately avoided noisy activity, what would surface them, and how long would that take?
- Could we demonstrate that we had removed an adversary? Do we retain the telemetry, evidence and forensic capability needed to support that conclusion?
- Which of our recovery assumptions remain credible if the honest answer to either of those questions is: “We do not know”?
The government has written down what it expects operators, departments and public bodies to prepare for.
The gap between those planning assumptions and an organisation’s ability to detect, contain and confidently recover from compromise may be one of the most important measures of UK cyber resilience.
No one assesses that measure consistently anywhere.
Sources
Cabinet Office, National Risk Register 2026, published 14 July 2026
https://www.gov.uk/government/publications/national-risk-register-2026
National Risk Register 2026 (full PDF)
https://assets.publishing.service.gov.uk/media/6a50d66b1228eb26a4cab76c/National_Risk_Register_2026.pdf
A Guide to the 2026 National Risk Register
https://assets.publishing.service.gov.uk/media/6a50d68d9e9c95844ae64caf/A_Guide_to_the_2026_National_Risk_Register.pdf
Designation of Data Infrastructure as Critical National Infrastructure, September 2024
https://questions-statements.parliament.uk/written-statements/detail/2024-09-12/hcws89
Cyber Security and Resilience (Network and Information Systems) Bill
https://bills.parliament.uk/bills/4035